Smart single-phase ON-LINE UPS with advanced DSP and 3-level technology, full digital control, zero transfer time, pure sine wave output and high efficiency with Power Factor = 1. The Prime Pro series provide excellent protection in installations with critical loads, by eliminating all electrical disturbances and power cuts. It is the ideal solution for the protection of servers, computer applications, security equipment, medical and laboratory equipment and lightweight industrial applications.
Features:
• Advanced DSP technology and 3 levels
• Automatic active power factor correction (APFC), input power factor up to 0.99
• Advanced digital parallel technology
• Hot battery swap
• Linear voltage degradation when it is low reducing battery discharge times, extending their life
• Intelligent battery management, automatic charge / charge balance control, charger idle control, 50% increase in battery life
• Ability to activate the UPS when there is no power supply (cold start)
• Adjustable start delay time when power is restored, reducing impact on mains or generator
• Automatic operation of fan speeds depending on temperature, reducing noise and extending its life
• Advanced multi-platform communications: RS232, USB, RS485, SNMP and dry contact interfaces
• Modern self-diagnosis function and event log
Warranties - Returns: | |
Money Return: | Repair - Replacement*: |
20 days | 24 months |
*Batteries are accompanied by a 12-month warranty |
Specifications: | |
Capacity | 6kVA / 6000W |
Input | |
Input wiring | Single-phase three-wire (1Φ + N + PE) |
Rated voltage | 208 / 220 / 230 / 240 Vac |
Voltage range | 110 ~ 176 Vac (linear derating between 50% and 100% load); 176 ~ 288 Vac (no derating) |
Rated frequency | 50 / 60 Hz (auto-sensing) |
Frequency range | 40 ~ 70 Hz |
Power factor | ≥ 0.99 |
Bypass voltage range | (- 40%, +15%) (settable) |
Total harmonic distortion (THDi) | ≤ 5% |
Output | |
Output wiring | Single-phase three-wire (1Φ + N + PE) |
Rated voltage | 208 (PF=0.9) / 220 / 230 / 240 Vac |
Voltage regulation | ± 1% |
Frequency | Synchronized to bypass in mains mode; 50 / 60 Hz ± 0.1% Hz in battery mode |
Waveform | Sinusoida |
Power factor | 1 |
Total harmonic distortion (THDv) | ≤ 1% (linear load); ≤ 4% (non-linear load) |
Crest factor | 3:1 |
Overload | 105% ~ 110% for 10 min, 110% ~ 125% for 1 min, 126% ~ 150% for 30 s |
Batteries | |
DC voltage | 192 Vdc (192 ~ 240 Vdc settable) |
Number of battery | 16 - 20 |
Inbuilt battery (standard model) | 12 V / 7 Ah x 16 |
Charging current | 1 A |
Recharge time | Standard model: 90% capacity restored in 8 hours |
System | |
Efficiency | ≥ 94% at 100% load, max. 95% at 60% load, ≥ 98% in ECO mode |
Transfer time | 0 ms |
Protections | Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure |
Max. number of parallel connections | 4 |
Communications | RS232 (standard), USB / RS485 / dry contacts / SNMP / battery temperature compensation (optional) |
Display | LCD + LED |
Other Specs | |
Operating temperature | 0℃ ~ 40℃ |
Storage temperature | (-25, 55)°C (without batteries) |
Relative humidity | 0 ~ 95% (non-condensing) |
Altitude | ≤ 1000 m, derating 1% for each additional 100 m |
IP rating | IP 20 |
Noise level at 1m | ≤ 55 dB |
Dimensions (WxDxH) (mm) | 191 x 465 x 711 |
Packaging dimensions (WxDxH) (mm) | 310 x 654 x 941 |
Net weight (kg) | 68 |
Gross weight (kg) | 77 |